Allin Plus-1 5 pk Pump kit with Five Standard charger and case
Allin Plus-1 5 pk Pump kit with Five Standard charger and case Air Sampling Pump Pump, Calibrator & Accessories Industrial Hygiene Selangor, Malaysia, Kuala Lumpur (KL), Klang Supplier, Suppliers, Supply, Supplies | Inter Products Marketing Sdn Bhd

AP Buck / 905150

Allin Plus-1 5 pk Pump kit with Five Standard charger and case (Flow Rate: 5 to 600 cc/min.)

Allin Plus-1 5 pk Pump kit c/w Allin-1 with single pack NiMH batteries (5 units), Luer hose adapter, shirt/hose clip, 3 feet of vinyl hose, non adjustable tube holder & adjustable Universal low flow holder for sorbent tube sampling, operating manuals, Five Standard charger 100-240VAC and a durable hard plastic case.

 
The BUCK Allin Plus 1 series is a personal air sampler suitable for use in location where flammable gases, vapors, dust, fibers or flyings
are present. It has steel fiber filled housing for RFI/EMI shielding, exclusive electronic circuit board for constant flow control, an LCD
display with 2 lines of 16 characters, a single diaphragm pump mechanism, and a rechargeable NiMH battery pack.
 
The purpose of this pump is to draw air contaminants in through a sampling media such as sorbent tubes, bubble impingers, long duration
color detector tubes; to gauge personnel exposure to gases, vapors, particulates, aerosols, etc.
 
No tools are required to operate this pump and a password protected keypad locking system provides uninterrupted operation. The
main display allows quick selection to RUN (for sampling) or MENU (to reset pumps data).
 
**Allin Plus models include data logging, programmable feature which allows the pump for unattended Start/Stop operation. Temperature
and Barometric Pressure compensation in STP mode. The PC link capability lets you download the sampling data into a PC with Windows
XP/ Windows 7 operating system using the RS232 COM port and the Buck PC link cable.
 
 

Features:

  • UL 913 and CAN/CSA-C22.2 Intrinsically safe certified: Suitable for use in Class I, II, III, Div 1 Groups A-G, T3 Hazardous locations.
  • **Allin Plus models capable of Data logging and can be programmed for multiple Start/ Stop and Duration Sampling.
  • **Temperature and Barometric Pressure Compensation available in the Allin Plus models.
  • High back pressure compensation, up to 36” of w.c.@300cc/min
  • Flow compensation for filter plugging and battery voltage.
  • “Auto-restart” within one minute of a flow fault.
  • Includes single pack battery and run time could be extended with the use of optional triple pack.
  • Battery pack rechargeable while attached or separately
  • Compact, rugged, and quiet.
  • Stainless steel belt clip with built-in tripod connector.
  • Key pad lock system.
 

Technical Specifications

Flow Range: 0.1-0.6 LPM (100-600 cc/min)
5 - 99 cc/min With Universal Low Flow Holder
 

Compensation Range:

600 cc/min up to 10” water back pressure
500 cc/min up to 25” water back pressure
300 cc/min up to 36” water back pressure
200 cc/min up to 25” water back pressure
100 cc/min up to 10” water back pressure
Accuracy: ± 5% of Compensation Range
 
Run Time (hrs) at different backpressure and flow rate (cc/min)


  Backpressure (inches of water)
Flow Rate  3”  5”  10”  15”  20”  30”  36”
100 24hr  23hr  21hr        
200 20hr  19hr  18hr  16hr  15hr  14hr  
300 19hr  18hr  16hr  14hr  13hr  11hr  10hr
400 15hr  14hr  12hr  11hr  10hr  9hr  
500 13hr  10hr  9hr  9hr  7hr    
600 9hr  8hr  6hr        

Low Flow using Universal Low Flow Holder 5 to 99cc/min 1-8 hours


Data Storage Flow rate, elapsed clock time, accumulated
Allin Plus Only volume, temperature, DP and any Flow Faults are logged in the memory for download to PC
Display Backlit LCD with 2 lines of 16 Characters
Normal Operation Battery Level, Flow Rate, Elapsed Time, Volume Collected, Timer & DP.
Flow Fault Displays Flow Fault, or Filter Off
Power Supply Single Pack, NiMH Batteries: 4.8V, 2.15 Ah
Triple Pack, NiMH Batteries 4.8V, 6.45 Ah
Charger Type Standard Wall Charger
Standard Charger Input Voltage 110 VAC - 240 VAC
Approvals UL913 and CAN/CSA-C22.2 Intrinsically safe certified. Suitable for use in Class I, II, III Div 1Groups A-G,T3 Hazardous locations.
Temperature Operating 32°F to 113°F (0°C to 45°C)
Storage 32°F to 113°F (0°C to 45°C)
Charging 50°F to 104°F (10°C to 40°C)
Case Polycarbonate steel fiber filled, RFI/EMI-shielded
Size 4.5”H x 4”W x 2”D (11.4 cm H x 10.2 cm W x 5 cm D)

Please leave your enquiry here, we will reply as soon as possible.


*only support gif, jpeg, jpg, png, pdf
Switch To Desktop Version