Sonus GA216I Class 2 Integrating Sound Level Meter
Sonus GA216I Class 2 Integrating Sound Level Meter Noise Safety and Environment Class2 Noise Meter / Noise Dosimeter Industrial Hygiene Selangor, Malaysia, Kuala Lumpur (KL), Klang Supplier, Suppliers, Supply, Supplies | Inter Products Marketing Sdn Bhd

Castle / GA216I

Sonus GA216I Class 2 Integrating Sound Level Meter

The Castle SONUS range of pocket sized sound level meters bring simplicity and power to the worlds of Noise at Work and Environmental sound monitoring. From a basic sound pressure meter to a combined sound and dosemeter, the range of systems covers a wide diversity of applications. The Castle Sonus GA216i is a feature packed instrument, fully compliant with IEC 61672:2013 Class 2. This meter gives simultaneous Leq and peak measurements for assessments to the Control of Noise at Work Regulations 2005. It has a high-specification measurement microphone and is cased in tough, crack resistant ABS plastic. It has a high-specification measurement microphone and is cased in tough, crack resistant ABS plastic.
 
Features of the GA216i:
Integrated equivalent level (Leq) measurement
Personal Sound Exposure Level (LEpd)
Sound Pressure (Lp) to 0.1 dB resolution
'A' and 'C' frequency weighting (toggle)
'Slow' and 'Fast' Time weighting (toggle)
Simultaneous measurement of Lp, Lmax, and Cpeak
Lmax - maximum Lp hold (rms.)
Cpeak - maximum peak level
Elapsed time (running time hrs, min, sec)
Single Event Sound Exposure Level (LAE)
Overload and Under-range indication
Battery condition (Life approx. 12 hours)
 
Operation: Using your Castle Sound Meter couldn't be simpler. Operate your new Sound Level Meter by pressing the cleverly designed keys to navigate around the meters many features and capabilities. Intuitively developed, it will seem like you've been using one for years.
 


Technical Specification

Applicable Standards IEC 61672-1:2002 (Integrating, Sound Exposure and Sound Level Meters)
IEC 60651:1979+A1+A2 (Sound Level Meters)
IEC 60804:2000 (Integrating Function
Microphone and Preamplifier Type 7052 Pre-Polarised ½” (13.2 mm) Free-Field, Electret Condenser Microphone: 20Hz – 8KHz ± 2dB –32 dB ± 3 dB re 1V/Pa Custom pre-amplifier design Typical actuator to free-field correction factor (based on 500Hz=0) is as follows
Display Back-lit LCD panel (8x1 Characters) Alpha-Numeric display for measured results
Level Range Measuring Range: 35-140
Linear operating range (IEC61672-1): 65dB
3 Measurement Ranges (IEC61672-1): 35-100 55-120 - Reference Range 75-140
Noise Floor Typical ’A’ Weighting <32 dB(A) rms.
‘C’ Weighting <38 dB(C) rms
Frequency Weighting ‘A’ and ’C’ to IEC 61672-1:2002 and IEC 60651:1979+A1+A2
Frequency Range 20 Hz - 8 kHz (including microphone) 1 Hz - 20 kHz (electrical characteristics)
Time Weighting Slow and Fast
Instrument Response Simultaneous rms. and Peak
Measurement Parameters Lp (Sound Pressure Level), Leq (Equivalent Sound Level), Lmax (maximum Level), Cpeak (Max. Peak Level), LEpd (Sound Exposure Level), LAE (Single Event Sound Exposure Level) Other Displays: Elapsed time, Overload, Battery Life
Calibration Software controlled 91.0 to 120.0 dB (1kHz) in 0.1 dB steps
Processing A to D Converter: 12-bit, 352Hz sampling Controller: 8MHz, micro-controller
Power Requirements Batteries: 1 x 6LR61 (size PP3), Life: >12 hours (alkaline batteries, continuous operation)
Dimensions 60mm (width) x 35mm (depth excluding pocket clip) x 135mm (height without microphone) or 210mm (height with microphone)
Weight 220gms (including battery)
Manuals Multi-language manuals*: French, German, Spanish and Italian